ECG

EDAN

 

SE-1010

View Image...
  DIMENSIONS 148mm (L) x 100mm(W) x 40mm (H)
  WEIGHT about 210g
  CONNECTION TO PC USB port
  POWER SUPLY DC 5V FROM USB PORT (ECG SAMPLING BOX POWER SUPPLY)
  INPUT CIRCUIT FLOATING INPUT CIRCUIT, PROTECTION FROM DEFBRILLATION AND PACE MAKER.
  LEAD STANDARD 12 LEADS
  ACQUISITION MODE 12 LEADS SIMULTANEOUSLY
  SAMPLING RATE 1000HZ
  A/D CONVERTER 12 BITS
  INPUT VOLTAGE RANGE +- 5m Vpp
  TIME CONSTANT 3.2s
  FREQUENCY RESPONSE 0.05Hz ~ 150Hz
  CALIBRATION VOLTAGE 1Mv +- 2%
  SENSITIVITY 2.5,5,10,20 (mm/Mv)
  INPUT IMPEDANCE 50M (10Hz)
  INPUT CIRCUIT CURRENT 50nA
  NOISE LEVEL 15u VP-Pv
  BASELINE DRIFT FILTER BASELINE FORWARD AND BACKWARD FILTER (PATENT PENDING)
  PATIENT LEAKAGE CURRENT 1pA (220V 240V)
  PATIENT AUXILIARY CURRENT 0.1Pa (DC)
  FILTER EMG FILTER:25hz /35Hz/45Hz/OFF
BASLINE DRIFT FILTER (PATENT PENDING): STRONG/WEAK/OFF
LOWPASS FILTER: 150Hz/100Hz/75Hz
AC FILTER:50Hz/60Hz
  CMRR 110dB
  RHYTHM LEAD SINGLE LEAD OR THREE LEADS SELECTABLE
  SAFETY STANDARD IEC II/ CF
     
 

SE12

View Image...  
  INPUT CIRCUIT FLOATING INPUT CIRCUIT, PROTECTION FROM DEFBRILLATION AND PACE MAKER.
  LEAD STANDARD 12 LEADS
  ACQUISITION MODE 12 LEADS SIMULTANEOUSLY
  A/D CONVERTER 12 BITS
  INPUT VOLTAGE RANGE +- 5m Vpp
  TIME CONSTANT 3.2s
  FREQUENCY RESPONSE 0.05Hz ~ 150Hz
  CALIBRATION VOLTAGE 1mV +- 2%
  SENSITIVITY 2.5,5,10,20 (mm/mV)
  INPUT IMPEDANCE 50M (10Hz)
  INPUT CIRCUIT CURRENT 50nA
  NOISE LEVEL 12.5 u VP-P
  ANTI BASLINE DRIFT AUTOMATIC
  PATIENT LEAKAGE CURRENT 1pA (220V 240V)
  PATIENT AUXILIARY CURRENT 0.1Pa (DC)
  FILTER EMG FILTER:25hz /35Hz/45Hz/OFF
DFT FILTER 0.05/0.15/0.25/0.5Hz
LOWPASS FILTER: 150Hz/100Hz/75Hz
AC FILTER:50Hz/60Hz
  CMRR 110Db
  RECORDING MODE AUTO/MANUAL/RHYTHM/R-R ANALYSE
  RHYTHM LEAD SINGLE LEAD OR THREE LEADS SELECTABLE
  SAFETY STANDARD IEC II/ CF
  POWER SUPPLY AC:100V-240V,50/60Hz  
  BATTERY BUILT IN RECHARGEABLE LI-ION
BATTERY: VOLTAGE= 14.4V, FOR ABOUT
100-PATIENT RECORDS
BUILT IN RECHARGEABLE LI-ION
BATTERY: VOLTAGE= 14.4V, FOR ABOUT
400-PATIENT RECORDS
  RECORDER THERMAL PRINTER
RECORD PAPER: ROLL AND Z-FOLD
216mm, 210mm PAPER WIDTH
  RECORD SPEED 5mm/s,10mm/s,12.5mm/s,25mm/s,50mm/s(+- 3%)
  DIMENSION 420mmx 330mmx105mm
DISPLAY: 320x240 DOT SINGLE COLOR LCD
420mmx330mmx120mm
800x600 MULTICOLOR LCD
  EXTERNAL INPUT/OUTPUT INPUT :> 100K^ : SENSITIVITY 10mm/v+- 5%
  OUTPUT 100^ : SENSITIVITY 1V/mV+- 5%
  COMMUNICATION INTERFACE Ethernet, RS232, USB
     
 

SE-3

View Image...
  INPUT CIRCUIT DEFIBRILLATOR PROTECTION BUILT –IN
  LEAD STANDARD 12 LEADS
  ACQUISITION MODE SINGLE LEAD 12 LEADS SIMULTANEOUSLY
  A/D CONVERTER 12 BITS
  MEASUREMENT RANGE +-5m Vpp
  TIME CONSTANT 3.2s
  FREQUENCY RESPONSE 0.05Hz ~ 150Hz
  CALIBRATION VOLTAGE 1mV +- 3%
  SENSITIVITY 2.5,5,10,20 (mm/mV)
  INPUT IMPEDANCE 10m^, 50m ^
  INPUT CIRCUIT CURRENT 50nA
  NOISE LEVEL 15 u VP-P
  ANTI BASLINE DRIFT AUTOMATIC
  PATIENT LEAKAGE CURRENT 10pA (220V 240V)
  PATIENT AUXILIARY CURRENT 0.1Pa (DC)
  FILTER EMG FILTER 35Hz (-3Db)
AC FILTER 50Hz/60Hz (-20Db)
EMG FILTER:25hz /35Hz/45Hz/OFF
DFT FILTER 0.05/0.15/0.25/0.5Hz
LOWPASS FILTER: 150Hz/100Hz/75Hz
AC FILTER:50Hz/60Hz
  CMRR 90Db, 110Db
  SAFETY STANDARD IEC II/ CF
  POWER SUPPLY AC: 100V-115V/220V-240, 50/60Hz BUILT-IN RECHARGEABLE ;I-ION BATTERY: VOLTAGE=14.4V MORE THAN 3 HRS CONTINOUS WORK UNDER BATTERY SUPPLY
  RECORDER THERMAL PRINTER
  RECORD PAPER 50mm x 30m, 80mm x20m
  Paper Speed 25mm/x 50mm/x (! 3%) 5mm/s6.25mm/s, 100mm/s, 12.5mm/s, 25mm/s, 50mm/s (l 3%)
  DIMENSIONS 288mmx210mm x70mm, WIEGHT:2.3KG (BATTERY), 2.5kg (with battery)
  DISPLAY 192x64 PIXELS LCD 320x240 PIXELS LCD (WIDE SCREEN)
192x04 PIXELS LCD (NARROW SCREEN)
    EXTERNAL INPUT/OUT PUT: INPUT> 100k^ : SENSITIVITY 10mm/V+-5% OOUTPUT<100^ sensitivity 1V/mV +- 5%
  COMMUNICATION INTERFACE RS232 ETHERNET, RS232

TRACES